固件
1.5.15
2022年9月23日 所有更新

Improvements

  • General enhancements

Known Issues

  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • To operate this version of MXA710 with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (Mac OS X)
  • To operate this version of MXA710 with Shure software or other Shure networked systems, reference the following list of recommended versions supported:
    • Designer 4.7.0
    • ANI22/ANI4IN/ANI4OUT 4.7.6
    • ANIUSB-MATRIX 4.7.17
    • MXA310 4.7.8
    • MXA910 4.7.13
    • MXN5-C 1.5.12
    • MXA-MUTE 1.5.16
    • Microflex Wireless 10.0.6
    • P300 4.7.17
    • ULXD4D/4Q 2.6.3
    • SCM820 1.4.3
    • Shure Update Utility 2.7.2
    • Shure Web Device Discovery 1.2.17
应用程式
1.8.2
2022年9月14日 所有更新

Important

  • Shure is currently looking into an issue with iOS 16 compatibility. Some functions may not work as expected.

Known Issues

  • The FPS and resolution combinations available for selection will vary based on the user’s phone.
  • If you monitor your recordings with Bluetooth earphones, you may hear artifacts, such as noise, while monitoring. If this occurs, we recommend changing the sample rate of your recordings. Some products may produce artifacts at 44.1 kHz, while others may do so for 48 kHz recordings. Please keep in mind that even if you hear artifacts while monitoring, they will not be present in the recordings themselves.

Notes

固件
1.3.276
2022年9月13日 所有更新

Important

  • Version 1.3.276 is a patch release to fix the root cause of a field issue that had prevented successful bootup on a few units. While the number of reports was extremely low, this update is highly recommended to avoid any potential risk of bootup issues in the future. Note that the prior two versions (1.1.161 and 1.3.220) are now removed from Shure Update Utility and Shure.com firmware archives.

Improvements

  • Bug fixes

Known Issues

  • Channel Names are not set in the initial attempt of ‘push-to-Dante’. Dante interface resets when Device Name is set.
    • Workaround: Channel Names are set on the 2nd attempt.
  • MXA920 LED does not stay on after a reboot if the light settings are set to Unmute = Blue, Mute = Red.  Other light combinations work as expected after reboot.
  • When a muted dynamic coverage area is moved when a dedicated coverage area has also been established, the mix output of the MXA920 has low-level audio from outside the dedicated coverage area limits.
    • Workaround: Unmute and Mute the dynamic coverage area after a dynamic coverage area is moved.

Notes

  • User Guide
  • Command Strings
  • Note that Talker Position Events are published for talkers in a coverage area regardless of the mute status of the coverage area.  To fully inform camera switching decision logic, subscribe to the Coverage Area Mute Status. See https://pubs.shure.com/command-strings for further information
  • To operate this version of MXA920 with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (Mac OS X)
  • To operate this version of MXA920 with Shure software or other Shure networked systems, reference the following list of recommended versions supported:
    • Designer 4.7.2
    • IntelliMix Room 3.3.0
    • ANI22/ANI4IN/ANI4OUT 4.7.6
    • ANIUSB-MATRIX 4.7.17
    • MXA310 4.7.8
    • MXA710 1.5.15
    • MXA910 4.7.13
    • MXN5-C 1.5.12
    • MXA-MUTE 1.5.16
    • P300 4.7.17
    • Shure Update Utility 2.7.2
    • Shure Web Device Discovery 1.2.17
固件
1.3.276
2022年9月13日 所有更新

Important

  • Version 1.3.276 is a patch release to fix the root cause of a field issue that had prevented successful bootup on a few units. While the number of reports was extremely low, this update is highly recommended to avoid any potential risk of bootup issues in the future. Note that the prior two versions (1.1.161 and 1.3.220) are now removed from Shure Update Utility and Shure.com firmware archives.

Improvements

  • Bug fixes

Known Issues

  • Channel Names are not set in the initial attempt of ‘push-to-Dante’. Dante interface resets when Device Name is set.
    • Workaround: Channel Names are set on the 2nd attempt.
  • MXA920 LED does not stay on after a reboot if the light settings are set to Unmute = Blue, Mute = Red.  Other light combinations work as expected after reboot.
  • When a muted dynamic coverage area is moved when a dedicated coverage area has also been established, the mix output of the MXA920 has low-level audio from outside the dedicated coverage area limits.
    • Workaround: Unmute and Mute the dynamic coverage area after a dynamic coverage area is moved.

Notes

  • User Guide
  • Command Strings
  • Note that Talker Position Events are published for talkers in a coverage area regardless of the mute status of the coverage area.  To fully inform camera switching decision logic, subscribe to the Coverage Area Mute Status. See https://pubs.shure.com/command-strings for further information
  • To operate this version of MXA920 with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (Mac OS X)
  • To operate this version of MXA920 with Shure software or other Shure networked systems, reference the following list of recommended versions supported:
    • Designer 4.7.2
    • IntelliMix Room 3.3.0
    • ANI22/ANI4IN/ANI4OUT 4.7.6
    • ANIUSB-MATRIX 4.7.17
    • MXA310 4.7.8
    • MXA710 1.5.15
    • MXA910 4.7.13
    • MXN5-C 1.5.12
    • MXA-MUTE 1.5.16
    • P300 4.7.17
    • Shure Update Utility 2.7.2
    • Shure Web Device Discovery 1.2.17
应用程式
3.7.4
2022年9月12日 所有更新

Important

  • Shure is currently looking into an issue with iOS 16 compatibility. Some functions may not work as expected.

Known Issues

  • A small percentage of users may receive a numerical error message while recording, such as “-1” or “66570.” These messages occur when there was an error writing to the device and are related to Apple’s new file system (APFS). One of these errors can occur even if your device has plenty of remaining storage. We recommend clearing up your device storage from the Settings screen, and if that doesn’t resolve the issues, doing a full restore from iTunes, consisting of backing up your device, wiping/restoring to factory settings, and restoring from the backup.
  • If you monitor your recordings with Bluetooth earphones, you may hear artifacts, such as noise, while monitoring. If this occurs, we recommend changing the sample rate of your recordings. Some products may produce artifacts at 44.1 kHz, while others may do so for 48 kHz recordings. Please keep in mind that even if you hear artifacts while monitoring, they will not be present in the recordings themselves.
  • When connected to iPad Pro via a USB-C cable, the MV88+ will pass audio and gain can be adjusted. However, the MOTIV apps will only display ‘external mic’, and the settings screen will not be available. Shure recommends using another device to configure the settings before using with iPad Pro. No adjustments can be made in real-time (except gain) on the Shure MOTIV apps when using an iPad Pro.

Notes

固件
4.7.17
2022年9月9日 所有更新

Improvements

  • Bug fixes

Known Issues

  • Shure Audio Encryption is not backward compatible; all devices must be on version 4.1+ firmware to use this feature
  • P300 Shure Audio Encryption sometimes has a brief crackling sound on audio after muting
  • Shure Update Utility and Designer may not allow downgrading of new P300s shipped with 4.2.7 or higher due to a platform update to support future functionality and USB improvements
  • P300s with firmware 4.3 require Designer versions 4.3 and higher and will NOT be supported in Designer versions 4.2.1 and earlier.
  • P300 firmware periodically adds new properties. The P300 may become undiscoverable if downgrading to firmware without the new properties and may need a factory reset to become discoverable.
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • To operate this version of P300-IMX with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (macOS)
  • To operate this version of P300-IMX with Microsoft Teams, reference the following minimum versions:
    • Microsoft Teams Desktop: 1.3.00.24755
    • Microsoft Teams Rooms: 4.6.20.0
  • To operate this version of P300-IMX with other Shure networked systems, reference the following list of recommended versions supported:
    • Designer 4.7.2
    • ANI22/ANI4IN/ANI4OUT 4.7.6
    • ANIUSB-MATRIX 4.7.17
    • MXA310 4.7.8
    • MXA710 1.5.14
    • MXA910 4.7.13
    • MXN5-C 1.5.12
    • MXA-MUTE 1.5.16
    • Microflex Wireless 10.0.6
    • Shure Update Utility 2.7.2
    • Shure Web Device Discovery 1.2.17
固件
4.7.17
2022年9月9日 所有更新

Improvements

  • Bug fixes

Known Issues

  • Shure Audio Encryption is not backward compatible; all devices must be on version 4.1+ firmware to use this feature
  • P300 Shure Audio Encryption sometimes has a brief crackling sound on audio after muting
  • Shure Update Utility and Designer may not allow downgrading of new P300s shipped with 4.2.7 or higher due to a platform update to support future functionality and USB improvements
  • P300s with firmware 4.3 require Designer versions 4.3 and higher and will NOT be supported in Designer versions 4.2.1 and earlier.
  • P300 firmware periodically adds new properties. The P300 may become undiscoverable if downgrading to firmware without the new properties and may need a factory reset to become discoverable.
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • To operate this version of P300-IMX with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (macOS)
  • To operate this version of P300-IMX with Microsoft Teams, reference the following minimum versions:
    • Microsoft Teams Desktop: 1.3.00.24755
    • Microsoft Teams Rooms: 4.6.20.0
  • To operate this version of P300-IMX with other Shure networked systems, reference the following list of recommended versions supported:
    • Designer 4.7.2
    • ANI22/ANI4IN/ANI4OUT 4.7.6
    • ANIUSB-MATRIX 4.7.17
    • MXA310 4.7.8
    • MXA710 1.5.14
    • MXA910 4.7.13
    • MXN5-C 1.5.12
    • MXA-MUTE 1.5.16
    • Microflex Wireless 10.0.6
    • Shure Update Utility 2.7.2
    • Shure Web Device Discovery 1.2.17
固件
9.0.8
2022年9月8日 所有更新

These release notes cover the following models: 

  • MXWAPT2/4/8 Access Point Transceivers

Important

  • Update any MXW devices which are below the minimum supported firmware 8.0.3 by using the Shure Update Utility (SUU) found here.  Please note – should the firmware version used be older than 5.2.2, it is advised to upgrade to version 5.2.2 first before updating to any subsequent more recent releases. Close the SUU when complete.

Improvements

  • Support for added hardware revisions

Known Issues

  • Multiple Primary Leader Clocks in Dante Controller might appear with mix of AES67 enabled on an MXW-APT as well as an Axient-Digital system on the same subnet

Notes

  • User Guide
  • Quick Start Guide
  • Crestron/AMX Control Strings
  • To operate this version of MXW with other Shure networked systems, see the following list of recommended software and firmware versions:
    • SCM820 1.4.3
    • Shure Web Device Discovery 1.2.17
    • Shure Update Utility 2.7.2
    • SystemOn 4.7.0
固件
9.0.8
2022年9月8日 所有更新

These release notes cover the following models: 

  • MXWAPT2/4/8 Access Point Transceivers

Important

  • Update any MXW devices which are below the minimum supported firmware 8.0.3 by using the Shure Update Utility (SUU) found here.  Please note – should the firmware version used be older than 5.2.2, it is advised to upgrade to version 5.2.2 first before updating to any subsequent more recent releases. Close the SUU when complete.

Improvements

  • Support for added hardware revisions

Known Issues

  • Multiple Primary Leader Clocks in Dante Controller might appear with mix of AES67 enabled on an MXW-APT as well as an Axient-Digital system on the same subnet

Notes

  • User Guide
  • Quick Start Guide
  • Crestron/AMX Control Strings
  • To operate this version of MXW with other Shure networked systems, see the following list of recommended software and firmware versions:
    • SCM820 1.4.3
    • Shure Web Device Discovery 1.2.17
    • Shure Update Utility 2.7.2
    • SystemOn 4.7.0
固件
9.0.8
2022年9月8日 所有更新

These release notes cover the following models: 

  • MXWAPT2/4/8 Access Point Transceivers

Important

  • Update any MXW devices which are below the minimum supported firmware 8.0.3 by using the Shure Update Utility (SUU) found here.  Please note – should the firmware version used be older than 5.2.2, it is advised to upgrade to version 5.2.2 first before updating to any subsequent more recent releases. Close the SUU when complete.

Improvements

  • Support for added hardware revisions

Known Issues

  • Multiple Primary Leader Clocks in Dante Controller might appear with mix of AES67 enabled on an MXW-APT as well as an Axient-Digital system on the same subnet

Notes

  • User Guide
  • Quick Start Guide
  • Crestron/AMX Control Strings
  • To operate this version of MXW with other Shure networked systems, see the following list of recommended software and firmware versions:
    • SCM820 1.4.3
    • Shure Web Device Discovery 1.2.17
    • Shure Update Utility 2.7.2
    • SystemOn 4.7.0